Best Feedline for HF Vertical Antenna | Greyline Kits

The Signal Lab · Feedline Doctrine

Complete Feedline System Kits

Every Greyline VDA is a complete antenna. What connects it to your shack is a system — and that system has to be configured correctly or the antenna cannot perform. This page specifies three complete feedline configurations: 450-ohm ladder line (lowest loss under high SWR, aerial installation), coaxial cable (simplest permanent installation, buried), and silicone HV wire in metallic flex conduit (lower loss than coax under high SWR, buriable, cost-effective). All three work. Choose by site, run length, and operating preference. Remember, every dB counts!

Read this first: what is already in your box

Every Greyline antenna ships with its feed system: the ladder line from the feedpoint, the hardware, and the RF choking that goes with it. Nothing on this page is required to get on the air. The three kits below are configurations — advice on the run from the antenna to the shack — not products. Where a Greyline part fits a position, it is named; the chokes by power rating are on the site for stations running an amplifier or wanting headroom.

Why this page exists

A Greyline antenna is not a commodity vertical. It is an off-center fed vertical dipole — a specific architecture with specific feedline requirements that differ from a standard coax-fed whip or a center-fed dipole. The support questions that come back most consistently are feedline questions. This page answers them completely, in advance, so you never have to ask.

Every QTH is different. The kit specs below are the correct starting point. Your specific run length, power level, and local RF environment will determine whether you need all components or a subset. The setup sequence tells you how to find out.

The Science Behind the Kit

Why the VDA Has Specific Feedline Requirements

The VDA feedpoint is elevated and positioned off-center along the radiator — not at the midpoint. This is what makes the antenna multiband and radial-independent. It is also what makes feedline management important.

In a perfectly center-fed dipole, the two antenna legs are equal length and the feedpoint currents are equal and opposite. The feedline is inherently balanced. In an off-center fed antenna, the two legs are unequal. The feedpoint currents are not perfectly equal on every band. This imbalance — which varies by frequency and feedline length — is the source of common-mode current on the feedline.

What is common-mode current?

A balanced feedline — whether 450-ohm ladder line or coax — is intended to carry two equal and opposite currents. The RF energy travels on the inside of the conductors as differential-mode current. Common-mode current is the unequal component that travels on the outside of the shield or on both conductors in phase. It does not contribute to radiation from the antenna. Instead it travels down the feedline toward the shack, causing noise on receive, RF feedback on transmit, erratic tuner behavior, and at high power levels, equipment damage and RF burns. Rauch W8JI documents this thoroughly: when the outside of the shield carries voltage, it becomes part of the antenna's return path.

The solution in both feedline paths is the same in principle: place a high-impedance choke at every point where common-mode current would otherwise flow freely. In the ladder line configuration that means two chokes — one at the feedpoint where imbalance originates, one at the wall where balanced line meets unbalanced coax. In the coax configuration it means one choke at the feedpoint to prevent the coax braid from becoming part of the antenna.

The key principle: for an OCF antenna, the choke at the feedpoint is the primary one. A choke placed only at the shack wall is better than nothing, but the feedline between the antenna and a wall-only choke can behave as part of the antenna on certain bands. This is why some bands may feel different from others in an improperly choked OCF installation. The feedpoint choke kills the problem at the source.

A note on power levels: at 100 watts you may not notice common-mode problems at all. Add a linear amplifier and the same antenna system that seemed fine will develop RF in the shack, tuner drift, and computer crashes. Common-mode current scales with power. The choke impedance required to suppress it also scales with power. The kits below are specified for legal-limit power. If you run 100 watts only, the 500W-rated choke is sufficient. If you run a kilowatt or more, use the 3500W or 5kW-rated options.

Kit 1 — 450-Ohm Ladder Line System

Lowest possible feedline loss — two chokes required, one optional

Best for: operators willing to manage a two-choke system in exchange for lower feedline loss under high-SWR multiband conditions. An open-wire balanced line has no significant dielectric loss — only conductor losses — and outperforms coax on most bands where the VDA presents elevated SWR. The difference is real and measurable, particularly on longer runs and on the low bands. This is the choice for the serious DX station where feedline efficiency matters and aerial routing is practical. Requires a wide-range ATU.

Routing note: 450-ohm ladder line cannot be buried. Route it through the air, away from metal structures and parallel to the antenna by at least 12 inches wherever possible. Where it must pass close to metal or walls, keep the run as short as possible and maintain spacing. Ice loading is a consideration in northern climates — account for it in your routing.

Component 1-A — Wall transition choke (required)

1:1 current choke, balanced studs in, SO-239 out

Spec: 1:1 current balun (choke) · rated for your power · 1.5–54 MHz · weatherproof housing · Greyline ships RF choking with every antenna; higher ratings on the site

What it does: Manages the balanced-to-unbalanced transition at the shack wall. Presents a high common-mode impedance to current trying to flow on the outside of the coax braid. Without this device, the coax braid becomes a third conductor — an unintended antenna radiating back into the shack.

Why 1:1 and not a transformer: The impedance on the ladder line varies widely across bands on a non-resonant antenna, and the wide-range ATU exists to handle exactly that. A 1:1 current choke does the one job the transition needs — stopping common-mode current — without adding a transformation the tuner did not ask for. Some operators run a 4:1 or 9:1 at this point for their own reasons, and it can work; it is not something we prescribe.

Placement: Outside the shack wall, at the exact point where the ladder line arrives. Connect the two ladder line conductors to the balanced stud terminals. Run the shortest possible coax from the SO-239 output into the shack. Weatherproof. Permanent outdoor installation.

Component 1-B — Antenna feedpoint choke (required)

Greyline feedpoint choke — included with every antenna; upgrade by power

1:1 current choke · 1–61 MHz · ships in your box · higher ratings: the 3500W Maxi and the 5kW beads

What it does: A 1:1 current choke at the antenna feedpoint chokes common-mode current at the source, before it can travel down the ladder line toward the shack. This is the most important choke in the system for an OCF antenna.

Why feedpoint placement is primary: Because the VDA is off-center fed, the feedpoint is where current imbalance originates on some bands. The feedline between the antenna and any downstream choke can itself behave as part of the antenna on certain frequencies — effectively making the choke at the wall less effective for those bands. Placing the choke at the feedpoint stops the problem at its origin.

Placement: At the antenna feedpoint connections, between the antenna's feed studs and the ladder line conductors. No coax involved at this position.

Any equivalent 1:1 current choke with balanced input and output, rated for your power level and 1.5–54 MHz, does the same job. Call us if you are unsure which rating you need.

Component 1-C — Station entry choke (optional, recommended at amplifier power)

Greyline Maxi Line Isolator, or any 5kW 1:1 coax current choke

1:1 current choke · coax in/out · 3500W Maxi · equivalents approx. $110–$125; choose a low-band or high-band core to match where you operate most

What it does: A second choke on the coax run between the wall choke (1-A) and the ATU. Provides a second line of defense against any residual common-mode current on the short coax run inside the shack. At legal-limit power with an amplifier, this is a meaningful addition.

Placement: Between the short coax coming from Component 1-A and your ATU input. Can be installed inside the shack at the ATU input or just outside the shack entry point.

Wiring diagram — signal path, Kit 1

VDA antenna (elevated OCF feedpoint)
↓ feed studs
1-B — Greyline feedpoint choke [feedpoint — balanced in/out — ladder-to-ladder]
↓ 450-ohm ladder line (run to shack wall, through air, away from metal)
1-A — 1:1 current choke [wall transition — balanced studs in, SO-239 coax out]
↓ shortest possible 50-ohm coax (LMR-400 class minimum)
1-C — Greyline Maxi or equivalent [optional station entry — SO-239 in/out — 1:1]
↓ coax to ATU input
ANTENNA TUNER (wide-range, coax or balanced output)

AMPLIFIER (if used)

RADIO

Setup sequence — Kit 1

1. Install Component 1-B at the antenna feedpoint before any RF is applied.
2. Route 450-ohm ladder line from feedpoint to shack wall. Keep it clear of metal.
3. Install Component 1-A at the shack wall exterior.
4. Run shortest possible coax from 1-A to ATU input. Install 1-C here if using it.
5. First session: 20 meters, 100 watts maximum. Tune. If the ATU tunes on 20M, it will tune on every band.
6. Check for RF feedback: touch the mic, the key, the computer — no tingle means clean.
7. If specific bands behave differently (won't tune, noisy, feedback), note which ones. That pattern tells you which choke position needs attention or upgrading.
8. Once confirmed clean at 100W, work up through the bands.
9. Add the amplifier last. Start at reduced power. Confirm each band. Then full power.

Total investment — Kit 1: the feedpoint choke ships with the antenna; add a 1:1 wall transition choke rated for your power. With the optional station-entry choke, two chokes. Choose the 3500W or 5kW-rated chokes for amplifier operation.

Kit 2 — Coaxial Cable System

Lowest complexity — one component required, one optional

Best for: operators who want a clean, permanent, buried installation with no feedline management. One wire from the antenna base to the shack. The feedline loss compared to ladder line is real but manageable — especially at a waterfront or rural QTH with good ground conductivity. Saltwater ground, elevated terrain, or a large lot all reduce the significance of feedline loss. With a kilowatt-class amplifier and a good location, coax-fed is still a formidable station.

Component 2-A — Antenna feedpoint choke (required)

Greyline RF Choke / Line Isolator — choose by power

1:1 current choke · SO-239 in/out · 1–61 MHz · 500W Mini · 3500W Maxi · 5kW slip-on beads · or any 5kW 1:1 coax current choke of the same class, approx. $110–$125

What it does: Stops common-mode current at the antenna feedpoint, preventing the coax outer braid from becoming a third conductor and an unintended radiator. Without this device, RF travels down the outside of the coax shield into the shack. The result is noise on receive, RF feedback on transmit, and equipment problems at high power.

Which rating: 500W for a barefoot station. 3500W Maxi for an amplifier. The 5kW beads for legal-limit operation with margin. Rate the choke above your amplifier's peak, not at it.

Placement: At the antenna feedpoint, coax side. This is the first device the coax connects to when it leaves the antenna. Mount it securely at the base of the antenna mast or at the feedpoint connection point. Weatherproof.

Component 2-B — Station entry choke (optional, recommended at amplifier power)

A second Greyline choke, matching the rating of 2-A

What it does: A second choke at the shack entry — between the coax coming in from outside and the ATU input. Catches any residual common-mode current picked up along the coax run (from nearby wiring, grounding differences, or induced RF from the antenna near-field). At legal-limit power, this is a worthwhile addition. If you run 100W it is optional. If you run a kilowatt, add it.

Coax selection guide

Cable Run length Power Notes
LMR-400 class Up to 100ft Up to 1.5kW Minimum recommended. Direct burial rated versions available.
LMR-600 class Any length Legal limit Recommended for permanent buried runs. Lower loss, handles full power cleanly. Bury it and forget it.
Hardline Long runs Any Best possible. Used by contest stations and commercial installations. If you can source it, use it.

PVC-jacketed coax is not recommended for permanent outdoor or buried HF runs — UV degradation and moisture ingress over time compromise the cable's electrical performance. Use polyethylene-jacketed or foam-dielectric direct-burial coax rated for burial.

Wiring diagram — signal path, Kit 2

VDA antenna (elevated OCF feedpoint)
↓ feed studs
2-A — Greyline RF Choke [feedpoint — SO-239 in/out — 1:1 choke]
↓ LMR-400 class minimum / LMR-600 class recommended (direct burial)
2-B — second Greyline choke [optional station entry — 1:1 choke]
↓ coax to ATU input
ANTENNA TUNER (desktop ATU works fine — coax in/out)

AMPLIFIER (if used)

RADIO

Setup sequence — Kit 2

1. Install Component 2-A at the antenna feedpoint before any RF is applied.
2. Run coax from 2-A to shack. Bury if possible — direct-burial-rated cable.
3. Install Component 2-B at the shack entry or ATU input (optional, add now or later).
4. First session: 20 meters, 100 watts maximum. Tune. Your ATU will find a match. If it tunes on 20M, it tunes everywhere.
5. Check for RF feedback. No tingle means clean installation.
6. Work through the bands at 100W. Then add power. Add the amp last.

Total investment — Kit 2: a Greyline choke from $65 (500W) to the 3500W Maxi. With optional 2-B, two chokes. Plus coax: LMR-600 class runs approximately $2.50–$3.50/foot depending on source. A 150-foot run = $375–$525. Budget accordingly for your run length.

Kit 3 — Two-Conductor HV Silicone Wire in Metallic Flex Conduit

Lower loss than coax under high SWR — buriable — cost-effective — requires installation care

Two silicone-insulated high-voltage wires run inside metallic flexible conduit. The conduit acts as a shield around the balanced pair, the silicone insulation is an excellent dielectric for HF, and the whole assembly can be buried. Under the high-SWR conditions that a multiband non-resonant antenna presents on most bands, this configuration loses less power than coaxial cable — and costs less per foot to install.

The configuration follows standard transmission-line physics as taught by Robert J. Zavrel Jr., W7SX, in Antenna Physics: An Introduction (ARRL): of the common wire insulations, silicone rubber is the best practical choice for a buried balanced line — excellent voltage breakdown, adequate loss tangent up into the VHF range, reasonable flexibility, and reasonable cost. Teflon (PTFE) is technically superior on loss tangent but prohibitively expensive. The balanced-line geometry is consistent with the transmission line physics in Kraus W8JK ( Antennas , McGraw-Hill) and the standard ARRL Handbook treatment of open-wire feedlines.

Why not PVC wire insulation?

PVC is the most common wire insulation and is disqualified for two reasons. First, most PVC-insulated wire is not rated for the high voltages present on a feedline operating at elevated SWR with full power. Second, PVC has a poor loss tangent at RF frequencies — it absorbs a measurable fraction of the RF energy passing through it as heat. At 60 Hz the loss tangent is negligible, which is why PVC works fine in household wiring. At HF and above, it is significant and measurable. Silicone rubber avoids both problems.

Component 3-A — Wire (required)

Silicone rubber-insulated 2-conductor wire — #16 AWG minimum, #14 AWG preferred — high-voltage rated

Search: "silicone mini split wire 2-conductor" or "16 AWG silicone high-temperature 2-conductor" — available from electrical suppliers. High-voltage rating of several thousand volts required.

Why silicone: Silicone rubber provides excellent voltage breakdown and adequate loss tangent up into the VHF range. It is also available in #16 AWG copper, the optimal wire size for this balanced-line application. Reasonable flexibility for pulling through conduit; reasonable cost. The dielectric comparison is standard material in Zavrel W7SX (ARRL) and the ARRL Handbook.

Wire gauge: #16 AWG is the minimum and preferred gauge. #14 AWG is also acceptable and reduces conductor resistance on longer runs.

Component 3-B — Conduit (required)

Metallic flex conduit with PVC jacket — ½" or ¾" ID

Flexible metallic conduit with attached PVC jacket — any electrical supplier or home center — approx. $0.75–$1.25/ft. Both ½" and ¾" interior sizes available.

Why metallic conduit: Burying a balanced line directly in soil creates problems — soil conductivity and moisture variation alter the line's impedance, and proximity to soil causes loss. The metallic conduit forms a shield around the balanced pair, decoupling the line from soil effects entirely. The outer PVC jacket weatherproofs the assembly for direct burial.

Size: ½" ID for two #16 AWG conductors. ¾" ID for two #14 AWG conductors or runs with multiple bends.

Alternative: Separate metal conduit inside non-metallic conduit achieves the same shielding at lower material cost. The jacketed combined product is easier to install.

Component 3-C — Shack-end transition (required)

Balanced-line ATU — or a 1:1 current choke at the wall transition point

Two paths work. If your ATU has balanced output terminals, the wire runs directly to them. If your ATU has coax output only, a 1:1 current choke at the wall (same spec as Kit 1 Component 1-A) handles the balanced-to-unbalanced transition; some operators choose a 4:1 or 9:1 here for their own reasons, which we do not prescribe. The Johnson Matchbox remains the classic example of an excellent balanced-line tuner — it tunes balanced line directly and uses an air-core balun rather than ferrite. The specific hardware choice is the operator's; the principle is to maintain the balanced-line characteristics until the ATU.

About half of Greyline buyers use a shack desktop ATU successfully. See the ATU selection guide for the full options discussion.

Why lower loss than coax under high SWR — the physics

A coaxial cable operating at elevated SWR loses more power than its matched-load specification indicates. The additional loss scales with SWR and run length. A balanced open-wire line with low-loss dielectric insulation has only conductor losses — no significant dielectric loss — and those conductor losses are substantially lower under high-SWR conditions than equivalent coax. This is well-established transmission line physics, consistent with Kraus W8JK ( Antennas ) and the ARRL Handbook transmission line loss tables.

The metallic conduit solves the one problem that makes direct-buried open wire impractical: soil coupling. Without the metallic shield, soil conductivity and moisture variation alter the line's impedance. The conduit prevents that, giving a balanced line the burial characteristics of coax while retaining the loss advantages of open wire.

Wiring diagram — signal path, Kit 3

VDA antenna (elevated OCF feedpoint)
↓ feedpoint studs to wire conductors
Two silicone HV wires inside metallic flex conduit
(buried run — stable impedance regardless of soil conditions)
↓ wire conductors emerge at shack entry
3-C — balanced ATU terminals [direct] OR 1:1 current choke [balanced in, coax out]

ANTENNA TUNER → AMPLIFIER (if used) → RADIO

Installation notes

1. Pull both wire conductors through the conduit before burial. Use wire-pulling lubricant on longer runs.
2. Leave 18–24 inches of wire extending from each end for connections.
3. Seal conduit ends with weatherproof silicone sealant to prevent moisture ingress.
4. Mark conductor polarity (which wire is which) at both ends before burial and keep it consistent throughout the installation.
5. Connect conductors directly to the VDA feedpoint studs. Weatherproof with self-amalgamating tape.
6. At the shack end, connect to balanced ATU terminals or to the balanced studs of a 1:1 current choke.
7. Bury at least 6 inches deep, 12 inches preferred.

Kit 3 vs. Kit 2 (coax): Under the high-SWR multiband conditions of a VDA installation, Kit 3 has lower feedline loss and lower material cost per foot than coax, and can be buried permanently. The trade-off is installation discipline — wire must be pulled through conduit, connections must be carefully weatherproofed, and conductor polarity must be tracked from feedpoint to shack. Kit 2 (coax) is plug-and-play. For short runs at modest power the practical difference is small and coax is the simpler choice. For long permanent runs at full power, the physics favors Kit 3.

Which Kit Is Right for You?

The Honest Comparison

Factor Kit 1 — Ladder Line Kit 2 — Coax Kit 3 — HV Wire / Conduit
Feedline loss Low under high SWR — measured advantage on long runs and low bands Higher than open wire under high SWR, manageable on short runs Lower than coax under high SWR — conductor losses only, no significant dielectric loss
Can be buried? No Yes — direct-burial coax Yes — metallic conduit with PVC jacket
Complexity Two chokes, aerial routing discipline, weather-sensitive One choke, bury and forget — simplest Wire pulling, polarity tracking, weatherproof connections required
Ice / weather Exposed aerial run — ice loading, rain detunes slightly (ATU corrects) Buried, no exposure Buried, no exposure
Material cost Ladder line inexpensive; feedpoint choke included; wall choke rated for your power LMR-600 class ~$2.50–$3.50/ft plus one Greyline choke (from $65) Silicone wire + conduit typically less per foot than LMR-600 class; one choke at wall
ATU requirement Wide-range tuner required Standard desktop ATU works fine Wide-range tuner required; balanced output preferred
Best for Aerial run where burial isn't possible; maximum low-band performance where ice/weather is not a concern Permanent buried installation — simplest, most reliable Permanent buried installation where feedline loss matters — long runs, high power

For most operators — including many RF engineers — Kit 2 (coax) is the right answer. It is permanent, reliable, plug-and-play, and on typical run lengths the feedline loss difference is not the factor that determines DX success. Kit 3 earns its place on long buried runs at high power where the loss math favors balanced line. Kit 1 (ladder line) is for operators who want the lowest loss on an aerial run and are willing to manage the system discipline that comes with it. All three paths work. The antenna, the location, and the operator are what make DX happen.

Engineering Source Validation

Every component spec in these kits — ladder line, coax selection, choke placement, ground plane practice — traces to the standing references in transmission line and RFI engineering: Maxwell W2DU on transmission lines, Brown K9YC on RFI and ferrites, Severns N6LF on ground systems, Rauch W8JI on common-mode current, Lewallen W7EL on baluns. All claims are held to the standard established in Zavrel W7SX ( Antenna Physics , ARRL 2020) and Kraus W8JK ( Antennas , McGraw-Hill). If a claim doesn’t survive that review, it doesn’t appear here. The Shelf We Read From →

Ham Radio is fun again. Pass it on... 73, Jon KL2A & the Greyline Performance Team — greylineperformance.com — 435-200-4902